Catalogs
Name | Manufacturer | Description | |||||
---|---|---|---|---|---|---|---|
136-024-86/60417 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 24" Maximum / 14" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 12,5", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Length | |||||
136-030-82/60400 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 30" Maximum / 14" Minimum, By-Pass Size - 2 F" npt, Plug Diameter - 13,5", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Len | |||||
136-030-84/60401 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 30" Maximum / 15" Minimum, By-Pass Size - 4 F" npt, Plug Diameter - 13,75", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Le | |||||
136-040-82/60402 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 40" Maximum / 19" Minimum, By-Pass Size - 2 F" npt, Plug Diameter - 18,5", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Len | |||||
136-040-84/60418 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 40" Maximum / 20" Minimum, By-Pass Size - 4 M" npt, Plug Diameter - 18,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Length | |||||
136-040-86/60419 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 40" Maximum / 20" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 18,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Length | |||||
136-040-88/60420 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 40" Maximum / 20" Minimum, By-Pass Size - 8 M" npt, Plug Diameter - 18,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Length | |||||
136-048-84/60403 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 48" Maximum / 23" Minimum, By-Pass Size - 4 F" npt, Plug Diameter - 23", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Lengt | |||||
136-048-86/60421 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 48" Maximum / 24" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 22,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
136-048-88/60422 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 48" Maximum / 24" Minimum, By-Pass Size - 8 M" npt, Plug Diameter - 22,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
136-060-84/60404 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 60" Maximum / 25" Minimum, By-Pass Size - 4 F" npt, Plug Diameter - 23,5", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Len | |||||
136-060-86/60423 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 60" Maximum / 30" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 23,6", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
136-060-88/60424 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 60" Maximum / 30" Minimum, By-Pass Size - 8 M" npt, Plug Diameter - 23,6", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
136-072-84/60405 | Petersen | Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 72" Maximum / 32" Minimum, By-Pass Size - 4 F" npt, Plug Diameter - 23,6", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Len | |||||
136-072-86/60425 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 72" Maximum / 32" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 23,6", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
136-072-88/60426 | Petersen | Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 72" Maximum / 32" Minimum, By-Pass Size - 8 M" npt, Plug Diameter - 23,6", Required Inflation - 15 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Eye Bolt Size - 0,47", Deflated Length | |||||
139-006-0172/60429 | Petersen | High Pressure Plug - Pipe Diameter - 6" Maximum / 6" Minimum, Plug Diameter - 5,6", Required Inflation - 172,8 psig, Pipeline Max, Head - 161 ft, Valve Type - 1/4" Quick, Deflated Length - 22,6" | |||||
139-008-086/60430 | Petersen | High Pressure Plug - Pipe Diameter - 8" Maximum / 6" Minimum, Plug Diameter - 5,6", Required Inflation - 86 psig, Pipeline Max, Head - 80 ft, Valve Type - 1/4" Quick, Deflated Length - 22,6" | |||||
139-010-0172/60431 | Petersen | High Pressure Plug - Pipe Diameter - 10" Maximum / 8" Minimum, Plug Diameter - 7,6", Required Inflation - 172,8 psig, Pipeline Max, Head - 161 ft, Valve Type - 1/4" Quick, Deflated Length - 25" | |||||
139-012-086/60432 | Petersen | High Pressure Plug - Pipe Diameter - 12" Maximum / 8" Minimum, Plug Diameter - 7,6", Required Inflation - 86 psig, Pipeline Max, Head - 80 ft, Valve Type - 1/4" Quick, Deflated Length - 25" | |||||
139-014-0172/60433 | Petersen | High Pressure Plug - Pipe Diameter - 14" Maximum / 12" Minimum, Plug Diameter - 10,9", Required Inflation - 172,8 psig, Pipeline Max, Head - 161 ft, Valve Type - 1/4" Quick, Deflated Length - 26,8" | |||||
139-016-0172/60435 | Petersen | High Pressure Plug - Pipe Diameter - 16" Maximum / 16" Minimum, Plug Diameter - 12,7", Required Inflation - 172,8 psig, Pipeline Max, Head - 161 ft, Valve Type - 1/4" Quick, Deflated Length - 34,1" | |||||
139-020-0172/60437 | Petersen | High Pressure Plug - Pipe Diameter - 20" Maximum / 20" Minimum, Plug Diameter - 18,6", Required Inflation - 172,8 psig, Pipeline Max, Head - 161 ft, Valve Type - 1/4" Quick, Deflated Length - 46,7" | |||||
139-020-086/60434 | Petersen | High Pressure Plug - Pipe Diameter - 20" Maximum / 14" Minimum, Plug Diameter - 12,7", Required Inflation - 86 psig, Pipeline Max, Head - 80 ft, Valve Type - 1/4" Quick, Deflated Length - 34,1" | |||||
139-024-086/60436 | Petersen | High Pressure Plug - Pipe Diameter - 24" Maximum / 20" Minimum, Plug Diameter - 18,6", Required Inflation - 86 psig, Pipeline Max, Head - 80 ft, Valve Type - 1/4" Quick, Deflated Length - 46,7" | |||||
141-0180/60516 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 18", Expanded Diameter - 19,25", Relaxed Diameter - 17,45", By-Pass Size - 1" | |||||
141-0200/60517 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 20", Expanded Diameter - 20,65", Relaxed Diameter - 19,15", By-Pass Size - 2" | |||||
141-0210/60518 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 21", Expanded Diameter - 22,1", Relaxed Diameter - 20,65", By-Pass Size - 2" | |||||
141-0240/60519 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 24", Expanded Diameter - 25,5", Relaxed Diameter - 23,55", By-Pass Size - 2" | |||||
141-0270/60520 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 27", Expanded Diameter - 27,7", Relaxed Diameter - 26,25", By-Pass Size - 2" | |||||
141-0300/60521 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 30", Expanded Diameter - 31", Relaxed Diameter - 29,25", By-Pass Size - 2" | |||||
141-0320/60522 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 32", Expanded Diameter - 34,48", Relaxed Diameter - 31,102", By-Pass Size - 2" | |||||
141-0360/60523 | Petersen | Hand Tightening Low Pressure Aluminum Body By-Pass Plug - Nominal Size - 36", Expanded Diameter - 36,8", Relaxed Diameter - 34,5", By-Pass Size - 2" | |||||
145-0024/60570 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 2,625" Maximum / 2,469" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0026/60571 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 2,812" Maximum / 2,625" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0028/60572 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 3" Maximum / 2,812" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0030/60573 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 3,188" Maximum / 3" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0031/60574 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 3,375" Maximum / 3,188" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0033/60575 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 3,562" Maximum / 3,375" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0035/60576 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 3,75" Maximum / 3,562" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/8 F npt | |||||
145-0037/60577 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 4,125" Maximum / 3,75" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/4 F npt | |||||
145-0041/60578 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 4,5" Maximum / 4,125" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/4 F npt | |||||
145-0045/60579 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 4,875" Maximum / 4,5" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/4 F npt | |||||
145-0048/60580 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 5,25" Maximum / 4,875" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/4 F npt | |||||
145-0052/60581 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 5,625" Maximum / 5,25" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/4 F npt | |||||
145-0056/60582 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 6" Maximum / 5,625" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/2 F npt | |||||
145-0060/60583 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 6,375" Maximum / 6" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/2 F npt | |||||
145-0063/60584 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 6,75" Maximum / 6,375" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/2 F npt | |||||
145-0067/60585 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 7,125" Maximum / 6,75" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 1/2 F npt | |||||
145-0071/60586 | Petersen | Mechanical High Pressure Test Plug - Pipe Size - 7,625" Maximum / 7,125" Minimum, Maximum Head Pressure - 100 psig, By-Pass Size - 3/4 F npt | |||||
Page: ←12345678910→ |


Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR


Датчик температуры THERMO EST SI/14 type SI 14.1 EExd


Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180