EX-Equipment > Catalogs

Catalogs

Name Manufacturer Description
129-020/60134  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 20" Maximum, Hot Tap - 10", Maximum Inflation - 40 psig, Pipeline Max, Head - 45 ft, Inflation Flange - 1 1/4" x 300 lb, Inflated Seal Length - 30"
129-024/60135  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 24" Maximum, Hot Tap - 12", Maximum Inflation - 37 psig, Pipeline Max, Head - 42 ft, Inflation Flange - 2" x 300 lb, Inflated Seal Length - 36"
129-030/60136  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 30" Maximum, Hot Tap - 12", Maximum Inflation - 30 psig, Pipeline Max, Head - 34 ft, Inflation Flange - 2" x 300 lb, Inflated Seal Length - 45"
129-033/60137  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 33" Maximum, Hot Tap - 12", Maximum Inflation - 30 psig, Pipeline Max, Head - 34 ft, Inflation Flange - 2" x 300 lb, Inflated Seal Length - 49"
129-036/60138  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 36" Maximum, Hot Tap - 12", Maximum Inflation - 27 psig, Pipeline Max, Head - 31 ft, Inflation Flange - 2" x 300 lb, Inflated Seal Length - 54"
129-042/60139  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 42" Maximum, Hot Tap - 16", Maximum Inflation - 21 psig, Pipeline Max, Head - 24 ft, Inflation Flange - 4" x 300 lb, Inflated Seal Length - 63"
129-048/60140  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 48" Maximum, Hot Tap - 16", Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Flange - 4" x 300 lb, Inflated Seal Length - 72"
129-054/60141  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 54" Maximum, Hot Tap - 16", Maximum Inflation - 12 psig, Pipeline Max, Head - 14 ft, Inflation Flange - 4" x 300 lb, Inflated Seal Length - 81"
129-060/60142  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 60" Maximum, Hot Tap - 18", Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Flange - 4" x 300 lb, Inflated Seal Length - 90"
129-066/60143  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 66" Maximum, Hot Tap - 20", Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Flange - 4" x 300 lb, Inflated Seal Length - 99"
129-072/60144  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 72" Maximum, Hot Tap - 24", Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Flange - 6" x 300 lb, Inflated Seal Length - 108"
129-084/60145  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 84" Maximum, Hot Tap - 24", Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Flange - 6" x 300 lb, Inflated Seal Length - 126"
129-096/60146  Petersen  Multi-FlexВ™ Line Stop Plug - Plug Diameter - 96" Maximum, Hot Tap - 30", Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Flange - 6" x 300 lb, Inflated Seal Length - 144"
134-016/60385  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 16" Maximum / 7,5" Minimum, Plug Diameter - 7,6", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Deflated Length - 25"
134-021/60386  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 21" Maximum / 10,75" Minimum, Plug Diameter - 10,7", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Deflated Length - 26,6"
134-024/60387  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 24" Maximum / 13" Minimum, Plug Diameter - 12,7", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Deflated Length - 34,1"
134-030/60388  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 30" Maximum / 14" Minimum, Plug Diameter - 13,5", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Deflated Length - 42,7"
134-040/60389  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 40" Maximum / 19" Minimum, Plug Diameter - 18,6", Required Inflation - 21,6 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Deflated Length - 46,7"
134-048/60390  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 48" Maximum / 23" Minimum, Plug Diameter - 22,6", Required Inflation - 21,6 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Deflated Length - 59"
134-060/60391  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 60" Maximum / 30" Minimum, Plug Diameter - 23,6", Required Inflation - 14,5 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Deflated Length - 90,6"
134-072/60392  Petersen  Multi-Size KevlarВ® Reinforced Sealing Plug - Pipe Diameter - 72" Maximum / 32" Minimum, Plug Diameter - 23,6", Required Inflation - 14,5 psig, Pipeline Max, Head - 13 ft, Valve Type - R 1/4", Deflated Length - 116,5"
135-040-8/60445  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 40" Maximum / 24" Minimum, By-Pass Size - 2", Maximum Inflation - 14,5 psig, Pipeline Max, Head - 22,7 ft, Deflated Width - 36,8", Deflated Length - 76"
135-040/60438  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 40" Maximum / 24" Minimum, Maximum Inflation - 14,5 psig, Pipeline Max, Head - 22,7 ft, Deflated Width - 36,4", Deflated Length - 84"
135-048-8/60446  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 48" Maximum / 32" Minimum, By-Pass Size - 2", Maximum Inflation - 13 psig, Pipeline Max, Head - 19,4 ft, Deflated Width - 50", Deflated Length - 92"
135-048/60439  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 48" Maximum / 32" Minimum, Maximum Inflation - 13 psig, Pipeline Max, Head - 19,4 ft, Deflated Width - 49,2", Deflated Length - 100"
135-064-8/60447  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 64" Maximum / 48" Minimum, By-Pass Size - 2", Maximum Inflation - 11,5 psig, Pipeline Max, Head - 16,2 ft, Deflated Width - 74,8", Deflated Length - 114"
135-064/60440  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 64" Maximum / 48" Minimum, Maximum Inflation - 11,5 psig, Pipeline Max, Head - 16,2 ft, Deflated Width - 73,2", Deflated Length - 128"
135-080-8/60448  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 80" Maximum / 64" Minimum, By-Pass Size - 2", Maximum Inflation - 8,6 psig, Pipeline Max, Head - 13 ft, Deflated Width - 100", Deflated Length - 148"
135-080/60441  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 80" Maximum / 64" Minimum, Maximum Inflation - 8,6 psig, Pipeline Max, Head - 13 ft, Deflated Width - 98", Deflated Length - 160"
135-088-8/60449  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 88" Maximum / 75" Minimum, By-Pass Size - 2", Maximum Inflation - 7,2 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 115", Deflated Length - 192"
135-088/60442  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 88" Maximum / 75" Minimum, Maximum Inflation - 7,2 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 115", Deflated Length - 192"
135-096-8/60450  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 96" Maximum / 96" Minimum, By-Pass Size - 2", Maximum Inflation - 7,2 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 147", Deflated Length - 221"
135-096/60443  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 96" Maximum / 96" Minimum, Maximum Inflation - 7,2 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 147", Deflated Length - 221"
135-108-8/60451  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug With By-Pass - Pipe Diameter - 108" Maximum / 108" Minimum, By-Pass Size - 2", Maximum Inflation - 5,8 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 166", Deflated Length - 264"
135-108/60444  Petersen  Multi-Size Pneumatic Pillow Shape Sealing Plug Without By-Pass - Pipe Diameter - 108" Maximum / 108" Minimum, Maximum Inflation - 5,8 psig, Pipeline Max, Head - 9,8 ft, Deflated Width - 166", Deflated Length - 264"
136-008-82/60406  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 8" Maximum / 4" Minimum, By-Pass Size - 2 M" npt, Plug Diameter - 3,8", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Length -
136-010-82/60407  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 10" Maximum / 6" Minimum, By-Pass Size - 2 M" npt, Plug Diameter - 5,8", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Length -
136-010-83/60408  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 10" Maximum / 6" Minimum, By-Pass Size - 3 M" npt, Plug Diameter - 5,8", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Length -
136-012-81/60396  Petersen  Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 12" Maximum / 5,63" Minimum, By-Pass Size - 1 F" npt, Plug Diameter - 5,5", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Le
136-012-8207/60409  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 12" Maximum / 6" Minimum, By-Pass Size - 2 M" npt, Plug Diameter - 5,6", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Length -
136-012-8212/60410  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 12" Maximum / 8" Minimum, By-Pass Size - 2 M" npt, Plug Diameter - 7,8", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Length -
136-012-84/60411  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 12" Maximum / 8" Minimum, By-Pass Size - 4 M" npt, Plug Diameter - 7,8", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Length -
136-016-8207/60412  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 16" Maximum / 7,5" Minimum, By-Pass Size - 2 M" npt, Plug Diameter - 7,25", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Lengt
136-016-8215/60397  Petersen  Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 16" Maximum / 7,5" Minimum, By-Pass Size - 2 F" npt, Plug Diameter - 7,38", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Le
136-016-84/60413  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 16" Maximum / 7,5" Minimum, By-Pass Size - 4 M" npt, Plug Diameter - 7,25", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,24", Deflated Lengt
136-021-82/60398  Petersen  Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 21" Maximum / 10,75" Minimum, By-Pass Size - 2 F" npt, Plug Diameter - 10,5", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated
136-021-84/60414  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 21" Maximum / 12" Minimum, By-Pass Size - 4 M" npt, Plug Diameter - 11,6", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Length
136-021-86/60415  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 21" Maximum / 12" Minimum, By-Pass Size - 6 M" npt, Plug Diameter - 11,6", Required Inflation - 29 psig, Pipeline Max, Head - 27 ft, Valve Type - R 1/4", Eye Bolt Size - 0,32", Deflated Length
136-024-82/60399  Petersen  Multi-Size Municipal Plug With Standard By-Pass - Pipe Diameter - 24" Maximum / 13" Minimum, By-Pass Size - 2 F" npt, Plug Diameter - 12,5", Required Inflation - 36 psig, Pipeline Max, Head - 34 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Len
136-024-84/60416  Petersen  Multi-Size Municipal Plug With Large By-Pass - Pipe Diameter - 24" Maximum / 14" Minimum, By-Pass Size - 4 M" npt, Plug Diameter - 12,7", Required Inflation - 22 psig, Pipeline Max, Head - 16 ft, Valve Type - R 1/4", Eye Bolt Size - 0,39", Deflated Length
Page: 12345678910

Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR

Датчик температуры THERMO EST SI/14 type SI 14.1 EExd

Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180