EX-Equipment > Catalogs

Catalogs

Name Manufacturer Description
107-010-3/60947  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 10" Maximum / 5" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 1 1/2 M, Deflated Length - 33"
107-012-2/60948  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 12" Maximum / 4" Minimum, Maximum Flushing Pressure - 100 psig, 2" npsh, Outlet Connection - 1 1/4 M, Deflated Length - 46"
107-012-3/60949  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 12" Maximum / 5" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 2 M, Deflated Length - 46"
107-015-3/60950  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 15" Maximum / 5" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 2 M, Deflated Length - 54"
107-016-3/60951  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 16" Maximum / 5" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 2 M, Deflated Length - 56"
107-018-3/60952  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 18" Maximum / 5" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 2 M, Deflated Length - 61"
107-024-3/60953  Petersen  Hydraulic Pipeline and Sewer Flushers - Pipe Diameter - 24" Maximum / 6" Minimum, Maximum Flushing Pressure - 100 psig, 2 1/2" nh, Outlet Connection - 2 M, Deflated Length - 76"
114-012H/60200  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 12" Maximum / 3,5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 1 1/2 M - 1/4 QC, Deflated Length - 30"
114-015H/60201  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 15" Maximum / 4" Minimum, Maximum Inflation - 20 psig, Pipeline Max, Head - 23 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 34"
114-016/60181  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 16" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 36"
114-016H/60202  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 16" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 36"
114-018/60182  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 18" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 40"
114-018H/60203  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 18" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 40"
114-020/60183  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 20" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 50"
114-020H/60204  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 20" Maximum / 4" Minimum, Maximum Inflation - 15 psig, Pipeline Max, Head - 17 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 50"
114-024/60184  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 24" Maximum / 5" Minimum, Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 59"
114-024H/60205  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 24" Maximum / 5" Minimum, Maximum Inflation - 10 psig, Pipeline Max, Head - 11 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 59"
114-030/60185  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 30" Maximum / 6" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 73"
114-030H/60206  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 30" Maximum / 6" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 73"
114-033/60186  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 33" Maximum / 6" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 74"
114-033H/60207  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 33" Maximum / 6" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 74"
114-036/60187  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 36" Maximum / 7" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 84"
114-036H/60208  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 36" Maximum / 7" Minimum, Maximum Inflation - 9 psig, Pipeline Max, Head - 10 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 84"
114-042/60188  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 42" Maximum / 7" Minimum, Maximum Inflation - 8 psig, Pipeline Max, Head - 9 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 96"
114-042H/60209  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 42" Maximum / 7" Minimum, Maximum Inflation - 8 psig, Pipeline Max, Head - 9 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 96"
114-048/60189  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 48" Maximum / 7" Minimum, Maximum Inflation - 5 psig, Pipeline Max, Head - 6 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 107"
114-048H/60210  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 48" Maximum / 7" Minimum, Maximum Inflation - 5 psig, Pipeline Max, Head - 6 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 107"
114-054/60190  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 54" Maximum / 9" Minimum, Maximum Inflation - 5 psig, Pipeline Max, Head - 6 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 139"
114-054H/60211  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 54" Maximum / 9" Minimum, Maximum Inflation - 5 psig, Pipeline Max, Head - 6 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 139"
114-060/60191  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 60" Maximum / 9" Minimum, Maximum Inflation - 4,5 psig, Pipeline Max, Head - 5 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 146"
114-060H/60212  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 60" Maximum / 9" Minimum, Maximum Inflation - 4,5 psig, Pipeline Max, Head - 5 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 146"
114-066/60192  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 66" Maximum / 9" Minimum, Maximum Inflation - 4 psig, Pipeline Max, Head - 4 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 159"
114-066H/60213  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 66" Maximum / 9" Minimum, Maximum Inflation - 4 psig, Pipeline Max, Head - 4 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 159"
114-072/60193  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass - Plug Diameter - 72" Maximum / 9" Minimum, Maximum Inflation - 3,5 psig, Pipeline Max, Head - 4 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 171"
114-072H/60214  Petersen  Multi-FlexВ™ Medium Duty Plug Without By-Pass with integral anchoring harness - Pipe Diameter - 72" Maximum / 9" Minimum, Maximum Inflation - 3,5 psig, Pipeline Max, Head - 4 ft, Inflation Port - 3 M - 1/2 QC, Deflated Length - 171"
118-004-06/60215  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 4" Maximum / 3,5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 3/4 M - 1/4 QC, Deflated Length - 84"
118-004-06S/60247  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 4" Maximum / 3,5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 3/4 M - 1/4 QC, Deflated Length - 84"
118-006-06/60216  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 6" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 1 M - 1/4 QC, Deflated Length - 86"
118-006-06S/60248  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 6" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 1 M - 1/4 QC, Deflated Length - 86"
118-008-08/60217  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 8" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 112"
118-008-08S/60249  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 8" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 112"
118-010-08/60218  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 10" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 114"
118-010-08S/60250  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 10" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 114"
118-012-08/60219  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 12" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 124"
118-012-08S/60251  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 12" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/4 QC, Deflated Length - 124"
118-015-08/60220  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 15" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 127"
118-015-08S/60252  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 15" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 127"
118-016-08/60221  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 16" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 128"
118-016-08S/60253  Petersen  Packers/Carriers Without By-Pass with Steam Packer 220В°F - Pipe Diameter - 16" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 128"
118-018-08/60222  Petersen  Packers/Carriers Without By-Pass - Pipe Diameter - 18" Maximum / 5" Minimum, Maximum Inflation - 25 psig, Pipeline Max, Head - 28 ft, Inflation Port - 2 M - 1/2 QC, Deflated Length - 130"
Page: 12345678910

Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR

Датчик температуры THERMO EST SI/14 type SI 14.1 EExd

Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180