02000-A-1642 Honeywell Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000)
02104-N-XSSC Honeywell Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box
04230-A-1010 Honeywell Hand Held Interrogator SAA Certified (4V0 software) for Optima, Optima Plus and Searchline Excel
05701-A-0120 Honeywell Engineering Interface Lead
05701-C-0130 Honeywell Model 5701 Scale Label -0 Catalytic -0 0-100% LEL
05701-N-6100 Honeywell 5701 Catalytic, Field Interface, Interconnect cable
05701-N-6119 Honeywell 5701 mA, Analogue output, High Integrity Relay, Interconnect cable
05704-C-0263 Honeywell Model 5704 Scale Label -0 mA -0 0-50ppm
05704-N-0114 Honeywell 5704 mA, Analogue output -0 sink, Relay Interface Assembly, Interconnect Cable
05708-N-1008 Honeywell 8W Rear Access Rack, 0 Blanking Panels
1226-9011 Honeywell XNX Transmitter Spare Pod, Millivolt Personality, ModBus Option
1991-0136 Honeywell Inlet Tubing, FEP Teflon 100' 1/4 x 1/8
20404-0300 Honeywell MST Extractive Module XT Low Flow (SF6, C5F8 only)
2106B1130 Honeywell 0-100% LEL Flam. Replacement Lid
2106B1204 Honeywell Sensepoint 0-100% LEL Flam. Sensor 3/4NPT
2106B1313 Honeywell Signalpoint NH3 0-50 ppm Toxic Sensor
2108B2101N Honeywell Hydrocarbon Searchpoint Optima Plus, UL/Inmetro
2108B2103H Honeywell Ethylene Searchpoint Optima Plus HART®, UL/Inmetro
2108N4001H Honeywell Ethylene calibration, with dust barrier, weather housing, deluge/heat shade, HART® output
2108N4400H Honeywell Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART® output
2108N5410N Honeywell Hydrocarbon calibration, for use in remote sampling systems for gas ranges 0–100 %v/v methane, 0–600,000 ppm propane and 0–400,000 ppm propane, fitted with remote gassing cell and flow housing
2110B2800 Honeywell Sensor Cartridge Locking Ring (except O2)
2110B3230 Honeywell Hydrogen Sulphide- 20ppm
2110B3370 Honeywell Nitrogen Dioxide- 12ppm
2110B3390 Honeywell Ozone- 0.4ppm
2110B3708 Honeywell Ethylene- 100%LEL
2110B3757 Honeywell Hydrogen- 100%LEL
2441-0027 Honeywell 8 terminal junction box for remote mounted cross duct systems ( 3 x 3/4"NPT entries)
S3KCAL Honeywell Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
S3KN1SS Honeywell Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)
SPSTAXH1SS Honeywell 0-50ppm Hydrogen Sulphide
SPXCDALMRXM Honeywell ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
SPXCDALMTXT Honeywell ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, LM25 with M20 Entry
SPXCDASMFX Honeywell ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
SPXCDHWES Honeywell Hex wrench for earth screw
SPXCDULNPX Honeywell UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
SPXCDUSNPXM Honeywell UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
SS2-A-C-E Honeywell Copper-Free Aluminum Housing UV/IR/VIS Electro-Optical Fire Detector, Latching Alarm Relay, ATEX Approved (2) M25
SS2-AM Honeywell Copper-Free Aluminum Housing UV/IR/VIS High-Speed Electro-Optical Fire Detector, Non-Latching Alarm Relay, ALARM and FAULT Relays, Class I, Division 1 Groups B, C, and D, FM, CSFM, and cFM Approved, 3/4 NPT
SS2-AN-SS-C-E Honeywell Stainless Steel Housing UV/IR/VIS Electro-Optical Fire Detector, Non-Latching Alarm Relay, ATEX Approved (2) M25
XNX-AMAE-FNNNN Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus™ output, configured for XNX toxic and Oxygen sensors
XNX-AMAV-FNCB1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL
XNX-AMAV-RNIC1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V
XNX-AMSI-NNNNN Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Searchpoint Optima Plus and Searchline Excel
XNX-AMSV-FNIV1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V
XNX-UTAE-RHNNN Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and Oxygen sensors
XNX-UTAV-RHIF1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL
XNX-UTAV-RNIC1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4”NPT entries, painted LM25 aluminium, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V
XNX-UTSV-FNIF1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL
XNXXSN1SS Honeywell XNX sensor Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)