Catalogs
Name | Manufacturer | Description | |||||
---|---|---|---|---|---|---|---|
ACSUPG-3500 | Honeywell | SOFTWARE VERSION UPGRADE WITH 3500 POINT DBPlease Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
ACSUPG-5000 | Honeywell | SOFTWARE VERSION UPGRADE WITH 5000 POINT DBPlease Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
ACSWBEPCTL | Honeywell | ACSELON WEB POINT CONTROLPlease Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
C7005A1037 | Honeywell | Pilot burner assembly with flame rod 6 in. length. For natural gas, .052 in. orifice, kanthal flame rod. | |||||
C7005B1035 | Honeywell | Pilot burner assembly with flame rod and ignition electrode. For natural gas, .051 in. orifice, kanthal flame rod. | |||||
C7005B1050 | Honeywell | Pilot burner assembly with flame rod and ignition electrode. For propane gas, .028 in. orifice, kanthal flame rod. | |||||
C7012A1145 | Honeywell | UV flame detector. 3/4" pipe mtg., 8 ft. leads, for use w/ rectification amplifiers.120V/50-60. Solid state. | |||||
C7012A1152 | Honeywell | UV flame detector. 3/4" pipe mtg., 8 ft. leads, for use w/ rectification amplifiers. 120V/50-60. 1 inch NPT solid state. | |||||
C7012A1160 | Honeywell | UV flame detector. 3/4" pipe mtg., 8 ft. leads, for use w/ rectification amplifiers. 120V/50-60. 1 inch NPT -40 Deg. Solid state. | |||||
C7012A1186 | Honeywell | UV flame detector. 3/4" pipe mtg., 8 ft. leads, for use w/ rectification amplifiers. 208V/50-60, solid state. | |||||
C7012A1194 | Honeywell | UV flame detector. 3/4" pipe mtg., 8 ft. leads, for use w/ rectification amplifiers. 240V/50-60. Solid state. | |||||
C7012C1042 | Honeywell | UV flame detector. 1" pipe mtg., 6 ft. leads. w/ explosion proof housing. For use w/ rectification amplifiers. 120V/50-60, Solid state. | |||||
C7012E1104 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 120V/50-60, Solid state. | |||||
C7012E1112 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 120V/50-60, 1 in. NPT, Solid state. | |||||
C7012E1120 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 120V/50-60, 1 in. NPT, -40 Degree Solid state. | |||||
C7012E1146 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 208V/50-60, Solid State. | |||||
C7012E1153 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 240V/50-60. Solid state. | |||||
C7012E1161 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 120V/50-60, 1 in. NPT 10 ft. cable. Solid state. | |||||
C7012E1187 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 220 volt 50 HZ Din approved with solid state circuit and -20 to +175 Deg F ambient temp. | |||||
C7012E1195 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 110V/50 HZ MSI approved. Solid state circuits -20 to 175 Deg F ambient temp. | |||||
C7012E1203 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 240 volts 50/60 HZ MSI approved with solid state circuit and -20 to +175 Deg F ambient temp. | |||||
C7012E1278 | Honeywell | Dynamic self check UV sensors for use w/ 7800 Series controls, R4140 and R7247C; w/ 3/4 in. mtg., 8ft. leads. 120V/50-60, 1 in. NPT, solid state circuit and -20 to +175 Deg F ambient temp with Brad Harris (Type 41310) connector. | |||||
C7012F1052 | Honeywell | Dynamic self check UV sensors for use w/7800 Series controls, R4140 and R7247C; w/ 1 in. mtg. 8 ft. leads. with explosion proof housing. 120V/50-60. Solid state. | |||||
C7012G1019 | Honeywell | UV flame detector for gas/oil flame. w/ cast case, cover. 3/4 in. pipe mtg. 8 ft. leads. Meets European stds. 220 volt 50 HZ Din approved solid state. | |||||
C7024E1001 | Honeywell | Solid state 24 VDC self checking ultraviolet flame detector. Will work only with RM7824A relay module & R7824C amp. Ambient temperature rating -40 to 175F. 24 VDC. | |||||
C7024F1009 | Honeywell | Solid state 24 VDC ultraviolet flame detector with self checking and explosion proof housing. Will work only with RM7824A relay module and R7824C amplifier. Self checking with explosion proof housing. | |||||
C7061A1012 | Honeywell | Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. Standard, for North American applications. | |||||
C7061A1020 | Honeywell | Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. Shutter supply voltage 115 or 230 VAC. | |||||
C7061A1038 | Honeywell | Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. Includes Brad Harrison connector. | |||||
C7061A1046 | Honeywell | Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. 1" NPT mount, Includes Brad Harrison connector. | |||||
C7061A1053 | Honeywell | Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. 1" NPT Mount, with 96" (8 foot) leadwires. | |||||
C7061F2001 | Honeywell | Dynamic self checking ultraviolet flame detector. Use w/R7861 amplifier. Ambient temp -40 to 175F. UV flame detector, explosion proof housing. | |||||
C7076A1007 | Honeywell | Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 120V/60HZ. | |||||
C7076A1015 | Honeywell | Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 100V/50-60HZ. | |||||
C7076A1031 | Honeywell | Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 220-240V/50-60HZ. | |||||
C7076D1027 | Honeywell | Solid state dynamic self-check UV sensor in NEMA 7 explosion proof housing. Rated for Class 1 Group C,D and Class II Group E,F,G hazardous areas. Use w/ R7476 AMP installed in R4140, R4075C,D,E , R4138C-D or FSP5075 1" Pipe MT. 120V/50-60HZ. | |||||
C7961E1006 | Honeywell | A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 3/4" NPT mount, with 96" (8 foot) lead | |||||
C7961E1022 | Honeywell | A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 1" NPT mount, includes Brad Harrison c | |||||
C7961F1004 | Honeywell | A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 1" NPT mount, with 96" (8 foot) leadwi | |||||
CARE-70NA-LNS | Honeywell | NEW CARE 7.1.03 WITH LNS. CD INCLUDES FULL INSTALLATION OF CARE WITH VOUCHER NUMBER LNS 3.0 DB XL5000 LITERATURE SRB AND THE HONEYWELL XL10 LNS PLUG-INS. CARE IS THE PROGRAMMINGPlease Note: This product can be sold by EECI only within a limited geogr | |||||
CR7890B1019 | Honeywell | ||||||
DH90A1007 | Honeywell | Includes DH90 dehumidifier, standard dehumidistat, ventilation controller. | |||||
DH90A1015 | Honeywell | Includes DH90 dehumidifier and YTH9421C1002 Visionpro IAQ thermostat. | |||||
DR-AAMPHP-AX | Honeywell | American Automatrix PHP over RS-232 or RS-485Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
DR-AAMPUP-AX | Honeywell | American Automatrix PUP over RS-232 or RS-485Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
DR-AC256-AX | Honeywell | AC256 over RS-232 or RS-485Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase by telephone. Thank you for understanding. | |||||
DR-NS-BAC-500 | Honeywell | Additional 500 BACnet Driver points Additional 500 point block for WEBStation-AX BACnet Driver.Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase b | |||||
DR-NS-BAC-AX | Honeywell | WEBStation-AX BACnet Driver WEBStation-AX BACnet Driver - Includes license for 500 BACnet points.Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase | |||||
DR-NS-MDB-500 | Honeywell | Additional 500 Modbus Driver points Additional 500 point block for WEBStation-AX MDB TCP Driver.Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualified purchase | |||||
DR-NS-MDB-AX | Honeywell | WEBStation-AX Modbus TCP Driver WEBStation-AX Modbus TCP Driver. Includes license for 500 Modbus TCP points.Please Note: This product can be sold by EECI only within a limited geographic area. Please call us toll-free at 1-800-360-EECI to make a qualifi | |||||
Page: ←12345678910…→ |


Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR


Датчик температуры THERMO EST SI/14 type SI 14.1 EExd


Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180