L4079B1041 | Honeywell | Range: 10-150 Psi (.7-10Kg/Sqcm). Max Diaphragm Pressure: 225 Psi. | |||||
L4079B1058 | Honeywell | 5-50 Psi Operating Range. Max Diaphragm Pressure: 85 Psi. | |||||
L4079B1066 | Honeywell | 20-300 Psi Operating Range. Max Diaphragm Pressure: 350 Psi. | |||||
L4079W1000 | Honeywell | Range: 10 To 150 Psi. Max Diaphragm Pressure: 225 Psi. | |||||
L4080B1295 | Honeywell | Range: 120F - 160F No Well Included | |||||
L4080B1352 | Honeywell | Range: 100 - 200F. 1-1/2 To 3 Insulation. 8F Differential. Less Well. Stop Factory Set At 150F. | |||||
L4081A1023 | Honeywell | Dual Aquastat Hi Limit 130-240F 10F Fixed Diff Lo Limit 110-220F 10-25 Adj Diff 3/4 Npt 1-1/2 Insul 3/4 Spud | |||||
L4081B1013 | Honeywell | Dual Aquastat Hi Limit 13O-240F 10F Fixed Diff Circulator 110-220F Well 3/4 Npt 3 Insul 3/4 Spud | |||||
L4081B1047 | Honeywell | Dual Aquastat. Hi Limit 130-240F. 10F Fixed Diff Circulator 110-220F. 10 To 25 Adj. Diff. 3/4 Npt. 1-1/2 Insulation | |||||
L4081B1096 | Honeywell | Dual Aquastat Hi Limit 130-240F 10F Fixed Diff Circulator 110-220F 3 Insulation Less Well | |||||
L408J1009 | Honeywell | 0 To 16 Oz/Sq Range, Spdt. Breaks R-B And Makes R-W On Pressure Rise. Replaces L408A1132 And L608A1046 | |||||
L408J1017 | Honeywell | 0 To 4 Psi Range, Spdt. Breaks R-B And Makes R-W On Pressure Rise.Replaces L408A1157 And L608A1053 | |||||
L408J1025 | Honeywell | 0 To 16 Oz/Sq Range, Spst. Makes R-W On Pressure Rise. Replaces L408B1131 | |||||
L408J1033 | Honeywell | 0 To 4 Psi Range, Spdt. Makes R-W On Pressure Rise. Replaces L408B1149 | |||||
L4103A1019 | Honeywell | High Limit Aquastat Controller with 100 F to 240 F operating temperature and 7 F ¦4 F Differential. | |||||
L4103A1100 | Honeywell | 160F Stop. Fixed Limit. Less Well Assy. | |||||
L480B1239 | Honeywell | Freeze Stat, Temperature Controller, Spdt, Range 20-60F, 20Ft Copper Capillary, 10F Fixed Diff, 20-60F Setpoint, 225F Max Bulb Temp, 20Ft Copper Cap, 250V Max, Automatic Reset. | |||||
L480G1044 | Honeywell | L480G 1044 Remote Stat | |||||
L482A1004 | Honeywell | 15-55 Degrees F, 5F Differential, 20 Ft Capillary, 2 Spst, One N. C. And One N. O. Contact, Manual Reset | |||||
L6006A1004 | Honeywell | Circulator Control, High Limit or Low Limit Aquastat Controller with 100 F to 240 F operating temperature and 5 F fixed Differential. | |||||
L6006A1012 | Honeywell | Aquastat Spdt Switching 100-240F Range. Horiz 1/2X3-3/8 Adj. Diff. 5-30F. | |||||
L6006A1145 | Honeywell | Super Tradeline. Vert Or Horiz Mt. With Well Adaptor. Stop At 240F. 5-30F Adj Diff, 3 In- Sulation. With Heat Conductive Compound | |||||
L6006A1244 | Honeywell | Range 100-240F. Adj. Diff. 5-30F. Less Well 3 Insul. Ansi Miswire Compliant | |||||
L6006C1018 | Honeywell | Aquastat Stop At 200F Spdt Switch For Unit Heater On High Limit Control. Range 65-200F Adj Diff. 5-30F Vert Or Horiz Mtg In Strap On Ap | |||||
L6008A1192 | Honeywell | Range 100-240F. Adj. Diff. 5-30F 66 Cap. 240F Stop. Conduct. Compound. Tradeline Conductive Compound. | |||||
L6008A1242 | Honeywell | Range 100-200F, Adj. Diff. 5-30F. Special For Kentucky Max Setpoint Of 200 Deg | |||||
L604N1009 | Honeywell | Pressuretrol Controllers, Auto recycle, 10 psi to 150 psi. | |||||
L6081A1010 | Honeywell | Tradeline. High Limit Range: 130 To 240F. Low Limit Range: 110-220F 3/4 Npt Spud. 3 Insul Less Well Assy, W/Well Adaptor & Heat Conduct Com | |||||
L7148F1075B | Honeywell | Range: 140 To 220 F. Connectors: Qc, W/Avd Plug. Bulk | |||||
L7224U1002 | Honeywell | 120 Vac Oil Electronic Aquastat® Controller with Enviracom communication and troubleshooting Leds. | |||||
L8100B1037 | Honeywell | 42 Capillary, 190F Eco Remote Bulb; 3/4 Npt; 2-1/4 Insul;3Insertion Control Well:3/4 Npt; 2-1/4 Insul; 5 Insert, No Offset | |||||
L8100B1094 | Honeywell | 54 In Cap. 190F Eco. Remote Bulb: 3/4 In Npt; 1 1/2 In Insul, 3 In Insert. Control: 3/4 In Npt, 2 1/4 In Insul, 4 1/2 In Insert. 140F Stop | |||||
L8100B1128 | Honeywell | Comb Water Heater And Eco Limit 100-180F Dual Bulb 58/42 Ratio 4-Wire Term Board. 1-1/2 Insul. Cover With Window | |||||
L8124A1007 | Honeywell | Triple Aquastat Relay Line Volt Burner Control 120V 60Hz. 130-240 Hi Limit. 10F Fixed Diff. 110-220F Lo Limit 10-25F Adj. Diff | |||||
L8124A1015 | Honeywell | Triple Aquastat Relay Line Volt Burner Control 120V 60Hz. 130-240F Hi Limit. 10F Fixed Diff 110-220F Lo Lim. 10-25F Adj Differential. | |||||
L8124B1039 | Honeywell | Tradeline. High Lim 130- 240F. Low Lim. 110-220F 120V 60Hz 1-1/2 Insul Univ Element Mnt. Less Well. Heat Cond. Comp. Special Adaptor | |||||
l8124c1003 | Honeywell | L8124C1003 Aquastat Relay | |||||
L8124C1102 | Honeywell | Less Well. Ground Screw 120V 60Hz 130-240F Hi Limit 10F Fix Diff 110-220 F. Low Limit 10-25F Adj Diff | |||||
L8124E1016 | Honeywell | Triple Aquastat Relay with High limit : 10 F fixed; low limit: 10-25 F adj. Differential. | |||||
L8124G1020 | Honeywell | Lim Range: Hi 130-240F. Lo: 110-220F 120V 60Hz Less Well W/Heat Cond Compound. Universal Element & Mounting | |||||
L8124L1011 | Honeywell | Limit Range:Hi 130-240F Lo: 110-220F. 120V 60Hz Less Well. Heat Cond Compound. Univ. Element & Horiz Or Vert Mount. | |||||
L8148A1017 | Honeywell | L8148A1017 Aquastat Relay. Less Well, Range 140-240F. Adj Stop At Hi Limit. Vert Or Horiz. Mount W/Ht Conductive Compound. Compound | |||||
L8148E1265 | Honeywell | Tradeline. Aquastat Relay With Molex Plug 120V 60Hz. Range 180- 240F 1-1/2-3 Insul Less Well. Spec Well Adaptor Heat Conduct Groundscrew | |||||
L8148E1299 | Honeywell | Low Volt, Vert. Mount 180-240F, W/50 Va Transformer, Well Adapt And Ht. Conductive Compound | |||||
L8148J1009 | Honeywell | 120V 60Hz. Range 140- 240F. Universal Mount Less Well. Heat Cond Compound. Stop Factory Set. Tradeline Compound Compound. | |||||
L91A1037 | Honeywell | Operating Range 0-15 Psi, Mid-Scale Throttling Range 7 0Z/Sq In., Max. Bellows Pressure 20 Psi | |||||
L91A1052 | Honeywell | Operating Range 5-150 Psi, Mid-Scale Throttling Range 5 Psi, Max. Bellows Pressure 225 Psi | |||||
L91A1078 | Honeywell | Operating Range 10-300 Psi, Mid-Scale Throt- Tling Range 12 Psi, Max. Bellows Press. 325 Psi, Knurled Adj. Knob, With Syphon | |||||
L91A1136 | Honeywell | Operating Range 10-300 Psi, Mid-Scale Throttling Range 12 Psi, Max Bellows Pressure 325 Psi, W/Knurled Adj. Knob ,Less Syphon | |||||
L91B1035 | Honeywell | Operating Range 0-15 Psi, Mid-Scale Throttling Range 1-12 Psi, Max. Bellows Pressure 20 Psi | |||||
Page: …←919293949596979899100…→ |


Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR


Датчик температуры THERMO EST SI/14 type SI 14.1 EExd


Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02