RM7890C  Honeywell  AUTOMATIC PRIMARY CONTROL, 4 OR 10 SEC PFEP, LOCKOUT OR RECYCLE ON FLAME FAILURE, STANDING PILOT AND 5 LEDS. INCLUDES DUST COVER.
RM7890D  Honeywell  PRIMARY CONTROL. SAFE START CHECK & INTERMITTENT PILOT. 15 OR 30 SEC PFEP LOCKOUT OR RECYCLE ON FLAME FAILURE. USE WITH FLAME RODS ONLY. HIGHER VOLTAGE FLAME ROD BIAS FOR IR HEATERS. LESS SHUTTER DRIVE OUTPUT.
RM7895A  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERMITTENT PILOT,LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW, 5 LEDS W/O AIRFLOW SWITCH CHECK FEATURE. INCLUDES DUST COVER.
RM7895B  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP, INTERMITTENT PILOT, LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW WITH AIRFLOW SWITCH CHECK, AND 5 LEDS. INCLUDES DUST COVER.
RM7895C  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERRUPTED PILOT,LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW W/O AIRFLOW SWITCH CHECK FEATURE, & 5 LEDS. INCLUDES DUST COVER.
RM7895D  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP, INTERRUPTED PILOT, LOCKOUT ON FLAME FAILURE OF LOSS OF AIRFLOW WITH AIRFLOW SWITCH CHECK, DELAYED MAIN VALVE, RUN TEST SWITCH. INCLUDES DUST COVER.
RM7895D1011  Honeywell  INTERR ON/OFF PRIM CTRL PREPURGE DYNAMIC
RM7895E  Honeywell  PRIMARY CONTROL. SAFE START CHECK CONFIGERABLE PREPURGE & INTERMITTENT PILOT. 15 OR 30 SEC PFEP LOCKOUT OR RECYCLE ON FLAME FAILURE. USE WITH FLAME RODS ONLY. HIGHER VOLTAGE FLAME ROD BIAS FOR IR HEATERS.
RM7895F  Honeywell  PRIMARY CONTROL. SAFE START CHECK CONFIGERABLE PREPURGE & INTERMITTENT PILOT. 10 OR 30 SEC. PFEP. LOCKOUT OR RECYCLE ON FLAME FAILURE USE W/FLAME RODS ONLY. HIGHER VOLTAGE FLAME ROD BIAS FOR IR HEATERS. AIRFLOW SWITCH CHECK.
RM7896A  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERMITTENT PILOT,LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW, 5 LEDS W/O AIRFLOW SWITCH CHECK FEATURE. INCLUDES DUST COVER. 15 SEC POSTPURGE.
RM7896B  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERMITTENT PILOT, LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW WITH AIRFLOW SWITCH CHECK, AND 5 LEDS. INCLUDES DUST COVER. 15 SEC POSTPURGE.
RM7896B1011  Honeywell  120v, 50/60 hz. switch check. 15 sec postpurge.
RM7896C  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERRUPTED PILOT,LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW W/O AIRFLOW SWITCH CHECK FEATURE, & 5 LEDS. INCLUDES DUST COVER. 15 SEC POSTPURGE.
RM7896D  Honeywell  PRIMARY CONTROL, 4 OR 10 SEC PFEP,INTERRUPTED PILOT, LOCKOUT OF FLAME FAILURE OF LOSS OF AIRFLOW WITH AIRFLOW SWITCH CHECK, DELAYED MAIN VALVE, RUN TEST SWITCH. INCLUDES DUST COVER. 15 SEC POSTPURGE.
RM7896D1019  Honeywell  120v, 50/60 hz. switch check. 15 sec postpurge.
RM7896D1027  Honeywell  120v, 50/60 hz. switch check. 15 sec postpurge. purge led instead of standard flame led. power led blinks alarm code on lockout.
RM7897A  Honeywell  AUTOMATIC PRIMARY CONTROL, SHUTTER DRIVE OUTPUT, 4 OR 10 SEC PFEP, LOCKOUT OR RECYCLE ON FLAME FAILURE OR AIRFLOW, 5 LEDS W/O PREIGNITION INTERLOCK INPUT. INTERRUPTED PILOT VALVE TERMINAL, 2ND STAGE MAIN VALVE FOR HIGH AN DLOW SYSTEMS. INCLUDES DUST COVER
RM7897C  Honeywell  AUTOMATIC PRIMARY CONTROL WITH DISPLAY, SHUTTER DRIVE OUTPUT, 4 OR 10 SEC PFEP, LOCKOUT OR RECYCLE ON FLAME FAILURE OR AIRFLOW AND 5 LED'S WITH PRE IGNITION INTERLOCK INPUT.
RM7898A  Honeywell  PRIMARY CONTROL WITH SELECTABLE PURGE TIME, 4 OR 10 SEC PFEP,INTERMITTENT AND INTERRUPTED PILOT, LOCKOUT & RECYCLE ON FLAME FAILURE OR LOSS OF AIRFLOW W/O DYNAMIC AIRFLOW SWITCH CHECK FEATURE, WITH PRE-IGNITION INTERLOCK INPUT & 5 LEDS. INCLUDES DUST COVE
RP418A  Honeywell  ELEC PNEU RELAY USED AS STOP & BLEED RELAY OR DIVERTING OR SELECTOR RELAY, LINE VOLTAGE, WALL MTD, WITH SPLICE BOX.
RP418B  Honeywell  ELEC PNEU RELAY USED AS STOP & BLEED RELAY OR DIVERTING OR SELECTOR RELAY, LINE VOLTAGE OPEN COIL NO SPLICE BOX, FOR PANEL MOUNTING.
RP470A  Honeywell  PNEUMATIC RELAYS. HIGHER OF TWO PRESSURES, 0-18 PSI OPERATING PRESSURE.
RP470B  Honeywell  LOCKOUT RELAY, LOWER OF TWO PRESSURES OR REPEATER RELAY. PILOT OPERATED, IN-LINE MOUNTING.
RP471A  Honeywell  SWITCHING RELAY/SINGLE POLE DOUBLE THROW, MODULATING PILOT SIGNAL, ADJUSTABLE 3-13 PSI SWITCHING POINT.
RP670A  Honeywell  PNEUMATIC SINGLE CIRCUIT SWITCHING RELAY, TWO POSITION SINGLE POLE DOUBLE THROW SWITCH. TWO POSITION PILOT SIGNAL REQUIRED. NON-ADJUSTABLE SWITCHPOINT.
RP670B  Honeywell  PNEUMATIC TWO CIRCUIT SWITCHING RELAY, TWO- POSITION DOUBLE POLE DOUBLE THROW SWITCH. TWO-POSITION PILOT SIGNAL REQUIRED. NON-ADJUSTABLE SWITCHPOINT.
RP818A  Honeywell  ELEC PNEU RELAY USED AS STOP & BLEED OR SELECTOR OR DIVERTING RELAY. LOW VOLTAGE WALL MTD SPLICE BOX SAME AS RP418A BUT LOW VOLTAGE VOLTAGE
RP818B  Honeywell  ELEC PNEU RELAY USED AS STOP & BLEED OR SELECTOR OR DIVERTING RELAY. LOW VOLTAGE PANEL MTD OPEN COIL NO SPLICE BOX SAME AS RP418B BUT LOW VOLT RP418B BUT LOW VOLT
RP913A  Honeywell  OPTIMATIC 7 INPUT LOAD ANALYZER RELAY. SELECTS LOWEST AND/OR HIGHEST OF 2-7 INPUT PRESSURES.
RP920A  Honeywell  PROPORTIONAL PNEUMATIC CONTROLLER, HIGH CAPACITY, SINGLE INPUT. REQUIRES TEMP, HUMIDITY, PRESSURE, OR OTHER SENSORS. 3-50% PROPORTIONAL BAND. ADJUSTABLE DIRECT/ REVERSE.INTERNAL .007 RESTRICTOR.
RP920B  Honeywell  PROPORTIONAL PNEUMATIC CONTROLLER DUAL INPUT. REQUIRES TEMPERATURE, HUMIDITY, PRESSURE, OR OTHER SENSORS. 3-50% PROPORTIONAL BAND. 5- 300% AUTHORITY RANGE. ADJUSTABLE DIRECT/ REVERSE. DIRECT OR REVERSE RESET.
RP920C  Honeywell  PNEUMATIC CONTROLLER WITH PROPORTIONAL PLUS INTEGRAL CONTROL MODE AND SINGLE INPUT. REQUIRES TEMPERATURE, HUMIDITY, PRESSURE, OR OTHER SENSORS.
RP920D  Honeywell  DUAL INPUT PNEUMATIC CONTROLLER WITH PROPORTIONAL PLUS INTEGRAL CONTROL MODE. REQUIRES TEMPERATURE, HUMIDITY, PRESSURE, OR OTHER SENSORS.
RP922A  Honeywell  RELAY, SUM OR AVERAGE TWO INPUT PRESSURES ADJUSTABLE RESTRICTION.
RP970A  Honeywell  PNEUMATIC CAPACITY RELAY. PROVIDES A HIGHER VOLUME OUTPUT AT SAME PRESSURE AS THE INPUT. ALSO APPLICABLE AS LOW- PRESSURE SELECTOR.
RP971A  Honeywell  PNEUMATIC SEQUENCING RELAY. PROVIDES A PROPORTIONAL OUTPUT IN FIXED RATIO TO INPUT CHANGE WITH ADJUSTABLE START-POINT.
RP972A  Honeywell  PNEUMATIC REVERSING RELAY. OUTPUT VARIES INVERSELY WITH INPUT WITH AN ADJUSTABLE OFFSET.
RP973A  Honeywell  AVERAGING RELAY. OUTPUT IS AVERAGE OF TWO INPUT PRESSURES.
RP975A  Honeywell  HESITATION RELAY, PROVIDES UNIT VENTILATOR SEQUENCE FOR LARGER AIR HANDLING UNITS.
S2Z3S3  Honeywell  s2z series - 3 zones w/ control (sweat)
S2Z3T3  Honeywell  s2z series - 3 zones w/ control (threaded)
S2Z4S3  Honeywell  s2z series - 4 zones w/ control (sweat)
S2Z4T3  Honeywell  s2z series - 4 zones w/ control (threaded)
S2Z8889-RP  Honeywell  honeywell zone valve control panel ( r8889d 1000 )
S437A  Honeywell  SAIL SWITCH, SPST CONTACTS CLOSE WITH INCREASED AIR VELOCITY 550-900 FPM ADJUSTABLE DIFFERENTIAL.
S437B  Honeywell  SAIL SWITCH, SPST CONTACTS CLOSE WITH INCREASED AIR VELOCITY 550-900 FPM ADJUSTABLE DIFFERENTIAL, WITHOUT CASE AND COVER.
S443A  Honeywell  POTENTIOMETER & TOGGLE SWITCH, 135 OHM, 180 DEGREE ROTATION AND DPDT TOGGLE SWITCH.
S445A  Honeywell  START STOP STATION FOR USE W/R485. R4138, R4075 LESS HOLD-IN RELAY.
S483B  Honeywell  WINTER WATCHMAN, 120V 120 WATT, MAKES CIRCUIT ON TEMPERATURE FALL FOR FREEZE WARNING. 30-60F RANGE.
S547A  Honeywell  MANUAL SWITCH, DPDT W/MOUNTING BRACKET. BRUSHED STEEL WALLPLATE.
Page: 201202203204205206207208209210

Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR

Датчик температуры THERMO EST SI/14 type SI 14.1 EExd

Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180