C7057A  Honeywell  CADMIUM SULFIDE PHOTO CELL SENSOR, USE WITH CR7075A TWO STAGE LIGHTING CONTROLLER.
C7061A  Honeywell  A DYNAMIC SELF CHECKING FLAME DETECTOR FOR SENSING THE UV RADIATION GENERATED BY THE COMBUSTION OF GAS, OIL, OR OTHER FUELS. USE WITH R7861A AMPLIFIER. AMBIENT TEMPERATURE RATING -40 TO 175F.
C7061A1012  Honeywell  Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. Standard, for North American applications.
C7061A1038  Honeywell  Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. Includes Brad Harrison connector.
C7061A1046  Honeywell  Dynamic self checking flame detector for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7861A amplifier. Ambient temperature rating - 40 to 175F. 1" NPT mount, Includes Brad Harrison connector.
C7061F  Honeywell  DYNAMIC SELF CHECKING ULTRAVIOLET FLAME DETECTOR. USE W/R7861 AMPLIFIER. AMBIENT TEMP -40 TO 175F. EXPLOSION PROOF HOUSING.
C7061F2001  Honeywell  Dynamic self checking ultraviolet flame detector. Use w/R7861 amplifier. Ambient temp -40 to 175F. UV flame detector, explosion proof housing.
C7076A  Honeywell  SOLID STATE DYNAMIC SELF-CHECK UV SENSOR FOR USE W/R7476 AMPLIFIER, INSTALLED IN R4140, R4075C,D,E, R4138C,D OR BURNER MGMT SYSTS; WITH TWO SENSITIVITY LEVEL ADJUSTMENT; 1 IN PIPE MTG; ENCLOSURE NEMA 4
C7076A1007  Honeywell  Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 120V/60HZ.
C7076A1015  Honeywell  Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 100V/50-60HZ.
C7076A1031  Honeywell  Solid state dynamic self-check UV sensor for use w/R7476 amplifier, installed in R4140, R4075C,D,E, R4138C,D or Burner mgmt systs; with two sensitivity level adjustment; 1 in. pipe mtg; Enclosure NEMA 4. 220-240V/50-60HZ.
C7076D  Honeywell  SOLID STATE DYNAMIC SELF-CHECK UV SENSOR IN NEMA 7 EXPLOSION PROOF HOUSING. RATED FOR CLASS 1 GROUP C,D AND CLASS II GROUP E,F,G HAZARDOUS AREAS. USE W/ R7476 AMP INSTALLED IN R4140,R4075C,D,E R4138C- D OR FSP5075 1" PIPE MT
C7076D1027  Honeywell  Solid state dynamic self-check UV sensor in NEMA 7 explosion proof housing. Rated for Class 1 Group C,D and Class II Group E,F,G hazardous areas. Use w/ R7476 AMP installed in R4140, R4075C,D,E , R4138C-D or FSP5075 1" Pipe MT. 120V/50-60HZ.
C7089A  Honeywell  PERFECT CLIMATE COMFORT CENTER OUTDOOR SENSOR. USE W/PC8900 & W8900. SENSES OUTDOOR TEMP FOR DISPLAY ON PC8900.
C7089B  Honeywell  OUTDOOR SENSOR FOR T8500 AND T8600 FAMILIES SENSES OUTDOOR TEMPERATURE FOR DISPLAY.
C7089H  Honeywell  AUTOMATIC HUMIDITY CONTROL OUTDOOR SENSOR. USE WITH H1008A AUTOMATIC HUMIDITY CONTROL WHEN INSTALLING WITH A HEAT PUMP OR MULTI-STAGE SYSTEM.
C7089U  Honeywell  OUTDOOR TEMPERATURE SENSOR FOR VISIONPRO TH7000 AND TH8000 SERIES THERMOSTATS.
C7100A  Honeywell  13 INCH AVERAGING SENSORS WITH VARIOUS OUTPUTS
C7100B  Honeywell  13 INCH AVERAGING SENSOR USED WITH W7080 MULTIZONE SYSTEM, THERMISTOR SENSING ELEMENT. REPLACES RANCO.
C7100C  Honeywell  13 INCH AVERAGING SENSOR USED WITH T775 PLATINUM THICK FILM SENSING ELEMENT, 3484 OHMS AT 77 DEG, 4.8 OHMS PER DEGREE SENSITIVITY.
C7100D  Honeywell  A PLATINUM AVERAGING SENSOR DESIGNED TO SENSE AIR TEMPERATURE IN DISCHARGE DUCTS OF ROOF TOP PACKAGED AIR COND. EQUIPMENT.
C7130A  Honeywell  PLATINUM SENSING ELEMENT MOUNTED IN ROOM THERMOSTAT CASE WITH COVER. FOR USE WITH W180 ZONE CONTROL SYSTEM.
C7130B  Honeywell  A TEMPERATURE SENSING DEVICE FOR MONITORING OR CONTROLLING TEMPERATURE IN CONJUNCTION WITH ELECTRONIC CONTROL.
C7150B  Honeywell  THERMISTER SENSOR, FOR MIXED OR DISCHARGE AIR DUCT MOUNT
C7170A  Honeywell  ENCAPSULATED PLATINUM SENSING ELEMENT USED WITH THE R7380 & W7100.
C7170B  Honeywell  A TEMPERATURE SENSING DEVICE FOR MONITORING OR CONTROLLING TEMPERATURE IN CONJUNCTION WITH ELECTRONIC CONTROL.
C7189A  Honeywell  PERFECT CLIMATE COMFORT CENTER REMOTE SENSOR. PROVIDES INPUT TO W8900 REMOTE MODULE TO SENSE TEMP IN INDOOR AIR SPACES. RESTRICTED TO PERFECT CLIMATE AUTHORIZED DISTRIBUTORS.
C7189U  Honeywell  INDOOR REMOTE TEMPERATURE SENSOR FOR VISIONPRO TH7000 AND TH8000 SERIES THERMOSTATS.
C7189U1005  Honeywell  RemoteSensorWhite ForVisionPro
C7232A  Honeywell  CO2 SENSORS FOR DCV (DEMAND-CONTROL VENTILATION) CONTROL. 0-10 OR 4-20 mA OUTPUT, 0-2000 ppm ADJUSTABLE.
C7232B  Honeywell  CO2 SENSORS FOR DCV (DEMAND-CONTROL VENTILATION) CONTROL. 0-10 OR 4-20 mA OUTPUT, 0-2000 ppm ADJUSTABLE.
C7400A  Honeywell  SOLID STATE ENTHALPY SENSOR 4-20 MA OUTPUT, DUCT MOUNT, USED WITH H705 OR W7459 OR OTHER SYSTEMS.
C7600A  Honeywell  SOLID STATE HUMIDITY SENSOR, 4-20 MA OUTPUT, DUCT MOUNT, USED WITH W7600, OR OTHER SYSTEMS.
C7600B  Honeywell  WALL MOUNT HUMIDITY SENSOR. USED WITH H775. 2-10 VDC OUTPUT
C7600C  Honeywell  SOLID STATE HUMIDITY SENSOR, 4-20 MA OUTPUT, POSITIVE SLOPE, USED WITH W7600, H775 OR OTHER SYSTEMS.
C7632  Honeywell  WALL MOUNT CO2 SENSOR - WITH FIXED 0-10VDC OUTPUT AND FIXED PPM RANGE OUTPUT. NO DISPLAY AND NO RELAY OUTPUT, WITH HONEYWELL LOGO.
C7650A  Honeywell  ADJ SOLID STATE THERMISTER TEMPERATURE SENSOR USED WITH W7459/ M7415, M7405
C7735A  Honeywell  DISCHARGE AIR TEMPERATURE SENSOR
C7750A  Honeywell  LINEARIZED 20K OHM DUCT TEMPERATURE SENSOR, 6" PROBE. (USE LINEARIZED 20K AS REPLACEMENT, FOR USE WITH SERIES 1000 XL10 ONLY).
C7770A  Honeywell  DUCT MOUNTED 20K NTC NON-LINEAR TEMPERATURE SENSOR WITH SIX (6) INCH PROBE.
C7772A  Honeywell  FLUSH MOUNT BRUSHED STAINLESS STEEL 20K OHM WALLPLATE SENSORS MOUNT ON 2X4 CONDUIT BOX.
C7835A  Honeywell  DISCHARGE AIR TEMPERATURE SENSOR
C7915A  Honeywell  LEAD SULPHIDE INFRARED DETECTOR, 3/4" NPT MOUNTING FOR USE WITH R7852 AMPLIFIERS.
C7927A  Honeywell  SOLID STATE FLAME DETECTOR. MUST BE USED WITH R7851B FLAME AMPLIFIER AND 7800 SERIES CONTROLS. 1/2" NPT MTG, (2) 4' LEADWIRES.
C7927A1008  Honeywell  UV SENSOR END VIEWING TEMP RANGE -4 TO 140F
C7961E  Honeywell  A DYNAMIC SELF CHECKING FLAME DETECTOR WITH SOLID STATE SENSOR, FOR SENSING THE UV RADIATION GENERATED BY THE COMBUSTION OF GAS, OIL, OR OTHER FUELS. USE WITH R7851C AMPLIFIER. AMBIENT TEMPERATURE RATING -40 TO 175F.
C7961E1006  Honeywell  A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 3/4" NPT mount, with 96" (8 foot) lead
C7961E1022  Honeywell  A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 1" NPT mount, includes Brad Harrison c
C7961F  Honeywell  A DYNAMIC SELF CHECKING FLAME DETECTOR WITH SOLID STATE SENSOR, FOR SENSING THE UV RADIATION GENERATED BY THE COMBUSTION OF GAS, OIL, OR OTHER FUELS. USE WITH R7851C AMPLIFIER. AMBIENT TEMPERATURE RATING -40 TO 175F.
C7961F1004  Honeywell  A dynamic self-checking flame detector with solid state sensor, for sensing the UV radiation generated by the combustion of gas, oil, or other fuels. Use with R7851C amplifier. Ambient temperature rating -40 to 175F. 1" NPT mount, with 96" (8 foot) leadwi
Page: 171172173174175176177178179180

Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR

Датчик температуры THERMO EST SI/14 type SI 14.1 EExd

Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180