EX-Equipment > Экстрактивный передатчик Honeywell Midas с датчиком

Экстрактивный передатчик Honeywell Midas с датчиком

00780-A-0160 Honeywell Right Angle Mounting Bracket For Hawke Junction Box
05701-C-0127 Honeywell Model 5701 Scale Label -0 Catalytic -0 0-20% LEL
05704-N-0112 Honeywell 5704 Catalytic, Analogue output -0 sink, Relay Interface Assembly, Interconnect
05704-N-0203 Honeywell 5704 mA, Quad Relay Interface
1226-0299 Honeywell XNX MPD Cartridge, IR Methane 0-100%LEL or 0-5.00% Vol.
1283K2237 Honeywell Apex Duct Mounting Adapter
210-190-045 Honeywell Killark Junction Box (excludes terminals)
2104B3111 Honeywell Medium Range Receiver Source UL
2106B1416 Honeywell Sensepoint H2 0-1000 ppm Toxic Sensor M20
2106B1545 Honeywell O2 Electrochemical Cell Exchange Kit
2106B1700 Honeywell Sensepoint H2S 0-20 ppm Toxic Sensor 3/4NPT
2108D0271 Honeywell Remote gassing pipe
2108N4101N Honeywell Ethylene calibration, with dust barrier, weather housing, deluge/heat shade
2108N4210N Honeywell Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, including remote gassing cell
2108N4600H Honeywell Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, HART® output
2108N4600N Honeywell Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade
2108N4610N Honeywell Hydrocarbon calibration, with dust barrier, weather housing, deluge/heat shade, including remote gassing cell
2108N4801H Honeywell Ethylene calibration, with dust barrier, weather housing, deluge/heat shade, HART® output
2110B2103 Honeywell Remote Sensor Junction Box UL Class I, Div 1 Groups BCD and Class I, Zone 1 CSA Class I, Groups BCD
9602-6705 Honeywell MST Sensor NH3 0-1000 ppm
9602-7300 Honeywell MST Sensor NO2 0-25.0 ppm
MPD-UTIC1 Honeywell XNX MPD Sensor, 3/4"NPT, UL/CSA approved, IR Carbon Dioxide 0-5.00%Vol.
MPD-UTIF1 Honeywell XNX MPD Sensor, 3/4"NPT, UL/CSA approved, IR Hydrocarbons (Propane Cal) 0-100%LEL
S3KAS3 Honeywell ATEX/IECEx approved Series 3000 MkIII toxic and Oxygen transmitter, Stainless Steel 316 and 2 x M20 entries
S3KTM Honeywell Replacement terminal module
S3KTMTS Honeywell Terminal screw and U' clamp (bag of 20)
S3KX1SS Honeywell Chlorine Dioxide 0-1.00ppm
S3KXSS1SS Honeywell Sulphur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)
S3KXSX1SS Honeywell Chlorine Dioxide 0-1.00ppm
SGPTPRMTL2 Honeywell 2 channel zener barrier MTL7787+
SPXCDULNHXM Honeywell UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4"NPT Entry, with ModBus
SPXCDULNTXFM Honeywell UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4"NPT Entry and ModBus
SPXCDULNTXOM Honeywell UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4"NPT Entry and ModBus
SPXCDXSCXSS Honeywell Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
SS4-A2-C-E Honeywell Aluminum UV/IR, ATEX, Hydrocarbon Fires, Non Latching Alarm LED, FM, cFM, ATEX, IECEx FOR Zone 1 (2) M25
SS4-FSHCOM Honeywell SS4 Module HART® Factory fitted, order with detector
TPWM4321 Honeywell 2 x mA input, 1 x mV input
XNX-AMAI-RHNNN Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional alarm and fault relay outputs and local HART® interface port, configured for Searchpoint Optima Plus and Searchline Excel
XNX-AMAV-MHIC1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted LM25 aluminium, with optional ModBus output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V
XNX-AMSI-NHNNN Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART® interface port, configured for Searchpoint Optima Plus and Searchline Excel
XNX-AMSV-FHCB1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL
XNX-AMSV-MHIV1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional ModBus output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V)
XNX-AMSV-NNIC1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V
XNX-AMSV-RNIV1 Honeywell XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V)
XNX-UTAI-NHNNN Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional local HART® interface port, configured for Searchpoint Optima Plus and Searchline Excel
XNX-UTAV-MNIF1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL
XNX-UTAV-MNIV1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4”NPT entries, painted LM25 aluminium, with optional ModBus output, including MPD IR methane sensor 0-100%LEL (0-5%V/V)
XNX-UTSE-RHNNN Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and Oxygen sensors
XNX-UTSV-RNIC1 Honeywell XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4”NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V
XNXXSM1SS Honeywell XNX sensor Nitrogen Monoxide 0-100ppm

To clarify the prices and terms of delivery please send requests by e-mail: LPTX@LPTX.RU.

We are looking forward to a long and beneficial cooperation!

Request form

refresh